0

Shopping Cart

Subtotal 0,00 €

View cartCheckout

Ermou 36, Amaliada
0

Shopping Cart

Subtotal 0,00 €

View cartCheckout

Fire protection study for solar parks

Fire protection study for solar parks

In line with the new circular of the Hellenic Fire Service Headquarters (ref. 60013 oik. F.701.45.4 / 22.10.2026). From site inspection and study to implementation of the measures, turnkey.

📞 Book a site inspection: +30 694 468 0410 ✉️ info@ecoenergysystems.gr

What changes with the new circular

In October 2026 the Hellenic Fire Service Headquarters introduced a single fire protection framework for ground-mounted photovoltaic stations in rural areas. The circular sets the minimum passive, preventive and active measures, the Fire Risk Assessment Study, the Emergency Response Plan and staff training. It also repeals, for photovoltaics, the older Order 44761/2011.

Which stations it applies to: all ground-mounted photovoltaic stations, regardless of capacity.
It does not apply to: PV on roofs, terraces, façades and canopies, small-scale self-consumption systems within a property, or floating stations. Storage stations and battery systems (BESS) combined with PV require a separate, dedicated fire protection study.

Deadlines

StationWhat applies
New stationFire protection study and Fire Risk Assessment Study before construction.
Existing stationAdaptation as far as practically feasible, within 3 years of publication, following a survey, site inspection and risk assessment.
Repowering, extension or capacity increaseThe new parts must comply in full.

The Risk Assessment Study is updated at least every five years, and after every substantial change (extension, repowering, equipment change, added storage), after a fire incident or a severe weather event.

What the station owner must do

  1. Fire protection study by a qualified engineer, which includes the Fire Risk Assessment Study and is filed in accordance with Article 4 of Fire Service Regulation 13/2021.
  2. Implementation of the measures that result from the study. Where required for the operating licence, correct installation is certified by a solemn declaration of a qualified engineer.
  3. Emergency Response Plan, made available to the local Fire Service.
  4. Training of the staff for operation and maintenance, and of external contractors.

Key measures in a solar park

Site, vegetation and access

  • A firebreak free of combustible vegetation, at least 3 m wide along the fence, within the site.
  • A vegetation management programme under the panels and around the equipment, especially before and during the fire season.
  • Passable access for fire engines and a perimeter road about 6 mwide, with turning points.
  • Fence at least 2,0 mhigh, with gates that allow fire engines through.

Electrical installation

  • A clearly visible, labelled DC-side isolation device for use by the Fire Service.
  • Lightning protection based on a risk analysis according to ELOT EN 62305, with equipotential bonding and earthing of the mountings.
  • Inverters and panels on a non-combustible surface with adequate ventilation, and cabling protected against mechanical damage, rodents and moisture.

Detection, fire fighting and signage

  • Automatic heat or smoke detection in inverter stations, medium-voltage rooms and the control centre, where the study requires it.
  • Portable fire extinguishers suitable for electrical fires, in the number and positions set by the study, and a fire blanket to ELOT EN 1869.
  • "PHOTOVOLTAIC INSTALLATION" signage, warning that the panels remain live, and a Fire Service information file at the entrance.

This list is indicative. The measures for each station are set by the Risk Assessment Study, depending on its size, technology (fixed mounts or trackers) and location.

How we work

  1. Site inspection and survey of the station and its surroundings: vegetation, proximity to forests, access, equipment.
  2. Fire protection study and Fire Risk Assessment Study, with drawings.
  3. Emergency Response Plan and staff training instructions.
  4. Implementation of the measures: signage, fire extinguishers, DC isolation devices, lightning protection, detection. A single contract, from the study to the installation.
Why ECO ENERGY SYSTEMS: we are engineers who design and build solar PV. We carry out installations and repowering of solar parks, so we know the installation from the strings to the main panel. The study we deliver works in practice, not just on paper.

Frequently asked questions

My park is small (e.g. 100 kW). Does this apply to me?

Yes. The circular applies to all ground-mounted photovoltaic stations, regardless of capacity. The only exceptions are systems on buildings, small self-consumption systems within a property and floating stations.

I have a park in operation. What is my deadline?

Existing stations must be adapted within 3 years of the circular's publication, as far as practically feasible. The first step is the site inspection and risk assessment. The sooner it is done, the more smoothly the works and costs can be planned.

I'm repowering or extending. What applies?

In a repowering, extension or capacity increase, the new parts of the station must comply fully with the circular.

I also have batteries (BESS) at the park.

Battery storage systems require a separate, dedicated fire protection study, and the interface with the PV system is examined in both studies. We can take on both.

How much does the study cost?

The cost depends on the size of the station, its location and the existing equipment, and is given after the site inspection. Contact us to book an appointment.

Book a site inspection for your park

We serve solar parks in Ilia, Achaia, Messinia and more widely in Western Greece and the Peloponnese.

📞 694 468 0410 ✉️ info@ecoenergysystems.gr

Or send us a message

Tell us the capacity and location of the park and we will call you to arrange a site inspection.

    Contact us

    ECO ENERGY SYSTEMS – Athanasios Fotopoulos, Mechanical Engineer · Ermou 36, Amaliada
    Source: Hellenic Fire Service circular "Fire Protection of Ground-Mounted Photovoltaic Power Stations in Rural Areas", ref. 60013 oik. F.701.45.4 / 22.10.2026 (ADA: 9ΧΦΞ46ΝΠΙΘ-Ε21).

    📞 Call now ✉️ Request a quote
    Viber WhatsApp